Problem Probable cause(s) Remedy
One or more of the fixtures is
completely dead.
Fixture not powered on.
Check that power is switched on and cables are
plugged in.
Primary fuse blown (located at the
mains inlet cable).
Disconnect fixture and replace fuse.
Secondary fuse(s) blown (located on
PCB inside the fixture base).
Disconnect fixture. Check fuses on PCB (F601 and
F602) and replace.
Fixtures reset correctly but all
respond erratically or not at all to the
controller.
The controller is disconnected from the
data link.
Connect controller.
XLR pin-out of the controller does not
match pin-out of the first fixture on the
link (i.e. signal is reversed).
Install a phase-reversing cable between the
controller and the first fixture on the link.
Fixtures reset correctly but some
respond erratically or not at all to the
controller.
Bad data link connection
Inspect connections and cables. Correct poor
connections. Repair or replace damaged cables.
Data link not terminated with 120Ω
termination plug.
Insert termination plug in output jack of the last
fixture on the link.
Incorrect addressing of the fixtures.
Check fixture address and protocol settings.
(page 12)
One of the fixtures is defective and
disturbs data transmission on the link.
Bypass one fixture at a time until normal operation
is regained. Do this by unplugging the XLR in and
out connectors and connecting them directly
together. Have the fixture serviced by a qualified
technician.
XLR pin-out on fixtures does not match
(pins 2 and 3 reversed).
Install a phase-reversing cable between the fixtures
or swap pins 2 and 3 in the fixture that behaves
erratically.
No light and “LERR” error message
displayed.
The ballast and transformer settings do
not match local AC voltage and
frequency.
Disconnect fixture. Check ballast and transformer
settings and correct if necessary.
Lamp blown Disconnect fixture and replace lamp.
Lamp not installed Disconnect fixture and install lamp.
Lamp cuts out intermittently.
Fixture is too hot.
Allow fixture to cool.
Reduce ambient room temperature.
Set fan speed to full.
Recalibrate temperature sensors.
The ballast and transformer settings do
not match local AC voltage and
frequency.
Disconnect fixture. Check ballast and transformer
settings and correct if necessary.
Kommentare zu diesen Handbüchern