14
MAC 600 (E) NT
Tests and readouts
The following readouts and tests are available from the control panel.
To calibrate temperature sensors
The temperature sensors are calibrated at the factory. Use this procedure if you suspect the calibration is faulty.
1 Turn off the fixture for 4 hours to allow it to cool to room temperature.
2 Measure the room temperature in Celsius. (To convert F° to C°, subtract 32° and multiply by 0.555.)
3 Power up the unit and allow it to reset.
4 Press [MENU] and [↓] and hold until “25” is displayed.
5 Scroll to the room temperature and press [ENTER].
Function Path Options Readout or effect
Usage counters
TIME/
Po H
Total hours of operation since fabricated.
RPoH
Hours of operation since counter reset. To reset, display
counter and press [↑
]
for 5 seconds.
LA H
Total hours of operation with lamp on since fabricated.
RLAH
Lamp hours since counter reset. Reset when relamping to
track lamp life. To reset, display counter and press [↑
]
for 5
seconds.
LSTR
Total number of lamp strikes since fabricated.
RSTR Number of lamp strikes since counter reset. To reset, display
counter and press [↑
]
for 5 seconds.
DMX readout
dMXL/
STCO
Decimal value of the DMX start code. The start code must be
0 for the MAC 600 (E) NT to function properly.
CH 0..CH14
DMX value (from 0 - 255) received for each channel. Note
that the channel number is 1 less than it is in the DMX
protocol.
Software versions
Ver/
CPU
CPU firmware version. Updates can be uploaded.
FEBA
Feedback circuit firmware version.
dISP
Display circuit firmware version.
Temperature readout
SPEC/TEMP/
HEAd
Head temperature in Celsius. Temperatures below 25° C are
shown as
-25; temperatures above 100° C are shown as
+100.
bASE
Base temperature in Celsius. Temperatures below 25° C are
shown as
-25; temperatures above 100° C are shown as
+100.
Tests
TSEQ RUN
Run a general test of all effects
SPEC/PCbT T1-T3
Run three tests of the circuit board.
For service use only.
SPEC/FTST/
WTST
Run an quality control effects test
MTST
Run a quality control movement test
SPEC/FTST/
STST
dIM
Run a quality control dimmer sensor test
COL
Run a quality control color wheel sensor test
bS
Run a quality control beam shaper sensor test