ROUBLESHOOTING
D
Problem Probable cause(s) Remedy
One or more of the fixtures
is completely dead.
No power to fixture.
Check that power is switched on and cables are
plugged in.
Primary fuse blown.
Replace fuse.
Secondary fuse(s) blown (located on
PCB inside base).
Check fuses on PCB and replace.
Fixtures reset correctly but
all respond erratically or
not at all to the controller.
The controller is not connected.
Connect controller.
XLR pin-out of the controller does not
match pin-out of the first fixture on the
link (i.e. signal is reversed).
Install a phase-reversing cable between the con-
troller and the first fixture on the link.
Fixtures reset correctly but
some respond erratically
or not at all to the
controller.
Poor data quality
Check data quality (page 13). If much under 100
percent, the problem may be a bad data link con-
nection, poor quality or broken cabling, missing
termination, or a defective fixture disturbing the
link.
Bad data link connection
Inspect connections and cables. Correct poor
connections. Repair or replace damaged cables.
Data link not terminated with 120Ω
termination plug.
Insert termination plug in output jack of the last
fixture on the link.
Incorrect addressing of the fixtures.
Check address setting.
One of the fixtures is defective and
disturbs data transmission on the link.
Bypass one fixture at a time until normal opera-
tion is regained: unplug both connectors and con-
nect them directly together.
Have the defective fixture serviced by a qualified
technician.
XLR pin-out on fixtures does not
match (pins 2 and 3 reversed).
Install a phase-reversing cable between the fix-
tures or swap pins 2 and 3 in the fixture that
behaves erratically.
Shutter closes suddenly. The color wheel, gobo wheel, or a
gobo has lost its index position and the
fixture is resetting the effect.
Contact Martin technician for service if the prob-
lem persists.
No light and “LERR” error
message displayed.
The power supply settings do not
match local AC voltage and frequency.
Disconnect fixture. Check settings (“AC power” on
page 7) and correct if necessary.
Lamp missing or blown
Disconnect fixture and replace lamp.
Lamp cuts out
intermittently.
Fixture is too hot.
Allow fixture to cool.
Clean fan.
Make sure air vents at control panel and front lens
are not blocked.
Turn up the air conditioning.
The power supply settings do not
match local AC voltage and frequency.
Disconnect fixture. Check settings (“AC power” on
page 7) and correct if necessary.
Table 6: Troubleshooting