MAC 350 Entouruser manualTM
10 MAC 350 Entour user manual• Connect one AC power phase to the terminal marked N or Phase 1 or L1.• Connect another AC power phase to the terminal
Data link 11Data linkA data link is required in order to control a MAC 350 Entour via DMX or synchronize fixtures in stand-alone operation.The MAC 35
12 MAC 350 Entour user manualPhysical installationThe MAC 350 Entour can be placed on a horizontal surface such as a stage or clamped to a truss in a
Physical installation 135.See Figure 3. Secure the fixture against clamp or bracket failure with a safety wire that can bear at least 10 times the we
14 MAC 350 Entour user manualSetupWARNING! Read “Safety Information” on page 3 before installing, powering, operating or servicing the MAC 350 Entour
Setup 15DMX address and protocolThe DMX address, also known as the start channel, is the first channel used to receive instructions from the controll
16 MAC 350 Entour user manual• When set to FULL, fans run permanently at full speed.• When set to SLNT (silent), light output is limited so that conv
Setup 17RDM Unique ID and manufacturer’s serial numberINFO→SNUM displays the fixture’s unique RDM ID number and the fixture’s serial number, both of
18 MAC 350 Entour user manualCalibrating effects 1. Apply power. 2. To calibrate focus, first remove the bottom head cover. Select SERV→CAL→FOCU and
Effects 19EffectsThis section describes the effects available in the MAC 350 Entour. Details of controlling effects via DMX or programming effects in
DimensionsAll dimensions are in millimeters©2010 Martin Professional A/S. Information subject to change without notice. Martin Professional A/S and al
20 MAC 350 Entour user manualAny of the six rotating gobos can be selected at an indexed angle, rotated, or shaken from side to side at an indexed an
DMX operation 21DMX operationWARNING! Read “Safety Information” on page 3 before installing, powering, operating or servicing the MAC 350 Entour.This
22 MAC 350 Entour user manualStand-alone operationWARNING! Read “Safety Information” on page 3 before installing, powering, operating or servicing th
Stand-alone operation 23Programming effects in a stand-alone scene using a DMX controllerInstead of programming effects in stand-alone scenes manuall
24 MAC 350 Entour user manual4. In synchronized operation, one master fixture issues commands to the other slave fixtures to “go to scene xx”, where
Service and maintenance 25Service and maintenanceWARNING! Read “Safety Information” on page 3 before servicing the MAC 350 Entour. Disconnect the fix
26 MAC 350 Entour user manualGobosThe gobos fitted to the MAC 350 Entour as standard are illustrated in Figure 6 on page 19. All gobos are interchang
Service and maintenance 27Effects access hatch and changing gobos and filtersWARNING! Hot surfaces. The MAC 350 Entour becomes hot in use. Either dim
28 MAC 350 Entour user manual3. To remove a rotating gobo, pull it gently towards the lens until you can slide it up and out of the two leaf springs
Service and maintenance 29• Airborne dust (from stage effects, building structures and fittings or the natural environment at outdoor events, for exa
Safety InformationThe following symbols are used to identify important safety information on the product and in this manual:WARNING! Risk Group 3 LED
30 MAC 350 Entour user manual• A PC running Windows 2000/XP• A PC-DMX interface supported by the Martin Software Uploader application (Martin Univers
Service and maintenance 31Circuit board layoutThe MAC 350 Entour has a large fan on the back of the head. Two types of this fan are installed at the
32 MAC 350 Entour user manualMAC 350 Entour DMX protocol8-bitmode16-bit modeDMX Value Percent Function110 - 1920 - 4950 - 6465 - 6970 - 8485 - 8990 -
MAC 350 Entour DMX protocol 33440 - 34 - 78 - 1112 - 1516 - 1920 - 2324 - 2728 - 3132 - 3536 - 3940 - 4344 - 4748 - 5152 - 5556 - 6667 - 7778 - 8889
34 MAC 350 Entour user manual890 - 56 - 1112 - 1718 - 2324 - 2930 - 3536 - 4142 - 4748 - 53,54 - 5960 - 6566 - 7172 - 7778 - 8384 - 8990 - 9596 - 101
MAC 350 Entour DMX protocol 359100 - 56 - 1112 - 1718 - 2324 - 2930 - 3536 - 4142 - 4748 - 53,54 - 5960 - 6566 - 7172 - 7778 - 8384 - 8990 - 9596 - 1
36 MAC 350 Entour user manual13 160 - 2 3 - 245246 - 251252 - 2550 - 2 3 - 245246 - 248249 - 251252 - 2550 - 245246 - 248249 - 251252 - 2550 - 2 3 -
Control menu 37Control menu Menu Item Options Notes (Default settings in bold print)ADDR1 – 501DMX address (default address = 1). Limited to 496 in
38 MAC 350 Entour user manualSARUNENAEnable stand-alone executionDISDisable stand-alone executionSAESINSingle fixture modeMASMaster modeSLASynchroniz
Control menu 39INFO(contd.)AIRFTOTL0 - 9999 service timer in hours. To reset timer to zero, press [Up] for 5 secs.STTMSet service timer alert: 100 -
• Refer any service operation not described in this manual to a qualified technician.PROTECTION FROM BURNS AND FIRE• Do not operate the fixture if the
40 MAC 350 Entour user manualDMX capture menuThe DMX capture menu in SA Æ PROG Æ GDMX contains the following options:Control panel shortcutsThe follo
Adjustment submenu 41Adjustment submenuThe SERVÆADJ menu is for use by service technicians when performing adjustments.Item Options NotesRSTReset fix
42 MAC 350 Entour user manualDisplay messagesMessage Appears when... What to doRST (Reset) ... the fixture is indexing effects at startup. Wait for
Troubleshooting 43Troubleshooting Problem Probable cause(s) RemedyFixture is completely dead.No power to fixture. Check power and connections.Fuse bl
44 MAC 350 Entour user manualSpecificationsPhysical Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications 45Construction Color . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
46 MAC 350 Entour user manual5 m DMX cable STP (2 pair), 5-pin male to 5-pin female XLR, IEC/UL-CL . . . . . . . . . . . . . . P/N 9161125010 m DMX c
www.martin.com • Olof Palmes Allé 18 • 8200 Aarhus N • DenmarkTel: +45 8740 0000 • Fax +45 8740 0010
ContentsDimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 MAC 350 Entour user manualNotes
Introduction 7IntroductionThank you for selecting the MAC 350 Entour™, an intelligent lighting fixture from Martin Professional™. This moving-head sp
8 MAC 350 Entour user manualUsing for the first time WARNING! Read “Safety Information” on page 3 before installing, powering, operating or servicing
AC power 9AC powerWARNING! Read “Safety Information” starting on page 3 before connecting the MAC 350 Entour to AC power.For protection from electric