4 Setting Up RoboColor III
Check voltage setting
Important! The voltage setting of the heads must match your local AC mains
supply.
The RoboColor III head is supplied in a 50 Hz or 60 Hz version. It is not possible
to rewire from 50 Hz to 60 Hz, or vice versa.
• The factory setting is printed on a label on the back of the head. Check the
setting against the table below and rewire if necessary, following the
instructions on page 15.
PREPARING THE CONTROLLER
Install a mains plug
Warning! For protection from dangerous electric shock, the fixture must
be grounded (earthed). The AC mains supply shall be have a
fuse or circuit breaker, and ground-fault protection.
The controller may be supplied without a plug on the mains cable. You will have
to fit a plug that conforms to your local mains outlet before you can connect the
unit to AC power. The double insulated mains cable contains three wires.
1 Connect the BROWN wire to the LIVE pin.
2 Connect the BLUE wire to the NEUTRAL pin.
3 Connect the YELLOW/GREEN wire to the EARTH pin.
50 Hz Model 60 Hz Model
Mains supply Ballast tapping Mains supply Ballast tapping
210V - 235V 230V 200V - 215V 210V
235V - 245V 240V 215V - 225V 220V
245V - 255V 250V 225V - 235V 230V
Wire Pin Marking Screw color (US)
brown live “L” yellow or brass
blue neutral “N” silver
yellow/green ground green