MAC 300
Standard 18° Lens
Optional wide angle diffuser
Luminous intensity (cd)
Degrees from center
Illuminance (lux or fc)
Distance (m or ft)
Field diameter (m or ft)
Distance (m or ft)
-20˚ -15˚ -10˚ -5˚ 0 5 10 15 20
0 5 10 15 20 25 30 35 40
0 5 10 15 20 25 30 35 40
Illuminance (lux or fc): . . . . . . . . . . . . . . . . . . . . . . . . . . .163,721 cd / distance2 (m or ft)
Illuminance with full frost (lux or fc): . . . . . . . . . . . . . . . . .28,820 cd / distance2 (m or ft)
Field diameter: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.32 x distance
Field diameter with full frost: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.63 x distance
Field angle: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18°
Field angle with full frost: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35°
Measurement conditions: . . . . . . . . . . . . . . . . . .230 V, 50 Hz; no color or effects applied
Measurement source: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Philips MSD 250/2, new
Luminous intensity (cd)
Degrees from center
Illuminance (lux or fc)
Distance (m or ft)
Field diameter (m or ft)
Distance (m or ft)
0 5 10 15 20 25 30 35 40
0 5 10 15 20 25 30 35 40
-40˚ -30˚ -20˚ -10˚ 0 10 20 30 40
Illuminance (lux or fc): . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14,258 cd / distance2 (m or ft)
Illuminance with full frost (lux or fc): . . . . . . . . . . . . . . . . . . .6356 cd / distance2 (m or ft)
Field diameter: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.12 x distance
Field diameter with full frost: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.33 x distance
Field angle: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59°
Field angle with full frost: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67°
Measurement conditions: . . . . . . . . . . . . . . . . . .230 V, 50 Hz; no color or effects applied
Measurement source: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Philips MSD 250/2, new