MAC Viper Wash™MAC Viper Wash DX™USER GUIDE
10 MAC Viper Wash User GuideDMX modesThe CONTROL MODE menu lets you set the MAC Viper Wash to one of the two DMX operating modes, basic 16-bit and ex
Control panel operations 11- When set to DMX, the lamp strikes automatically when the fixture begins to receive DMX data, and lamp power is shut down
12 MAC Viper Wash User GuideDMX signal monitoringThe MAC Viper Wash provides data on the DMX signal it is receiving in the DMX LIVE menu. This inform
Adjusting settings via DMX 13Adjusting settings via DMXCertain fixture settings and parameters can be adjusted from the DMX controller on the Fixture
14 MAC Viper Wash User GuideChanging calibration offsets using DMXThe Fixture control/settings DMX channel allows effects to be calibrated by changin
RDM 15RDMThe MAC Viper Wash can communicate using RDM (Remote Device Management) in accordance with ESTA’s American National Standard E1.20-2006: Ent
16 MAC Viper Wash User GuideSoftware service functionsService utilitiesThe control panel SERVICE menu provides utilities for technicians rigging or s
Software service functions 17Loading and storing default calibration offsetsIn the CALIBRATION menu, LOAD DEFAULTS lets you load the factory default
18 MAC Viper Wash User GuideTo install firmware in the MAC Viper Wash:1. Download the firmware ‘.MU3’ file from the MAC Viper Wash support page on th
DMX protocol 19DMX protocolApplicable when running MAC Viper Wash firmware version: 1.0.0Basic 16-bit Mode16-bit Extended Mode DMX Value Percent Func
© 2013 Martin Professional A/S. Information subject to change without notice. Martin Professional A/S and all affiliated companies disclaim liability
20 MAC Viper Wash User Guide890 - 255 0 - 100Iris – MAC Viper Wash DX onlyOpen → closedFade 09100 - 255 0 - 100Internal barndoor 1 – MAC Viper Wash D
DMX protocol 2118 190 - 910 - 1415 - 1920 - 2425 - 2930 - 3435 - 3940 - 4445 - 4950 - 5455 - 5960 - 6465 - 6970 - 7475 - 7980 - 8485 - 8990 - 9495 -
22 MAC Viper Wash User GuideMSB = Most significant byteLSB = Least significant byte-27Reserved for future use-28Reserved for future useBasic 16-bit M
Control panel menus 23Control panel menusApplicable when running firmware version 1.0.0.Menu level 1 Menu level 2 Menu level 3 Menu level 4 Notes (De
24 MAC Viper Wash User GuidePERSONALITY(continued)EFFECT SHORTCUTONEffects take shortest route during changes, crossing open positions if necessaryOF
Control panel menus 25* Menu available only when the fixture is connected to mains power. All other menus are available in mains- and battery-powered
26 MAC Viper Wash User GuideService and display messagesThe MAC Viper Wash gives service and maintenance information by displaying a large 3- or 4-ch
Service and display messages 27* Adjustment should only be carried out by a qualified service technician with Martin™ service documentation.** High t
28 MAC Viper Wash User GuideCEPTCOM ERR P/TCommunication error between main processor and pan/tilt circuit (an error here will also probably block co
Service and display messages 29FANHD M FAN ERRHead mid cooling fan has stopped running. Lamp is shut down. Error cleared when fixture is reset.FBEPPA
ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30 MAC Viper Wash User GuideUPLDDMX UPLOAD ERRORAn error occurred during upload via DMX. Check cabling and connections, and then restart.YEERYELLOW E
MAC Viper Wash™MAC Viper Wash DX™SAFETY AND INSTALLATION MANUAL
DimensionsAll measurements are given in millimetersThis minimum center-to-center distance can be reduced if pan limits are set via the control menus55
ContentsSafety Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety InformationThe following symbols are used to identify important safety information on the product and in this document:Warning! The MAC Viper W
Safety Information 5America the cable must be 12 AWG minimum conductor size, SJT or better. In the EU the cable must be 2.5 mm², HAR compliant.• Befo
6 MAC Viper Wash Safety and Installation GuideIntroductionThank you for selecting the Martin™ MAC Viper Wash™. This moving-head washlight features:•
Physical installation 7Physical installationWarning! The MAC Viper Wash has a powerful pan motor. The torque reaction when the head is panned suddenl
8 MAC Viper Wash Safety and Installation GuideClamping the fixture on a truss1. Check that the rigging clamps are undamaged and can bear at least 10
Physical installation 96. See Figure 6. Install a safety wire that is approved as a safety attachment for the weight of the fixture by looping it thr
4 MAC Viper Wash User GuideIntroductionThis User Guide covers the Martin MAC Viper Wash™, including the MAC Viper Wash DX™ model. The MAC Viper Wash
10 MAC Viper Wash Safety and Installation GuideAC powerWarning! For protection from electric shock, the fixture must be electrically connected to gro
AC power 11Connecting to an AC mains power sourceThe MAC Viper Wash power cable can be hard-wired to a building installation circuit or fitted with a
12 MAC Viper Wash Safety and Installation GuideDMX data linkThe MAC Viper Wash has 5-pin locking XLR sockets for DMX and RDM input and output (see Fi
Service and maintenance 13Service and maintenanceWarning! Read “Safety Information” on page 4 before servicing the MAC Viper Wash.Warning! Disconnect
14 MAC Viper Wash Safety and Installation GuideLamp lifeMonitor lamp hours using the resettable LAMP ON TIME counter in the INFORMATION control menu.
Service and maintenance 157. Close the lamp access cover and tighten the screw to secure the cover before reapplying power.8. After installing a new
16 MAC Viper Wash Safety and Installation GuideLubricationThe MAC Viper Wash does not require lubrication under normal circumstances. The slides for
Service and maintenance 17If one or more of these factors is present, inspect fixtures within their first few hours of operation to see whether clean
18 MAC Viper Wash Safety and Installation Guide7. Remove the old air filter element from the filter housing and put the new element into position wit
Service and maintenance 19Servicing the IBD moduleThe MAC Viper Wash DX is supplied with an IBD (internal barndoors) projection module installed that
Effects 5EffectsThis section gives details of the effects that can be controlled via DMX. See the DMX protocol table on page 19 for details of the ch
20 MAC Viper Wash Safety and Installation Guide6. The color filters in the IBD module’s color wheel are interchangeable. If you need to replace one,
Service and maintenance 2110. See Figure 21. Route the IBD module and color mixing module wiresets through the cutout in the head chassis (arrowed) a
22 MAC Viper Wash Safety and Installation GuideUsing the fixtureBefore using the fixture, download and read the latest version of the MAC Viper Wash
Troubleshooting 23Troubleshooting Problem Probable cause(s) RemedyOne or more of the fixtures is completely dead.No power to fixture.Check that power
24 MAC Viper Wash Safety and Installation GuideSpecificationsPhysicalLength (base). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications 25Connections AC power input . . . . . . . . . . . . . . . . . . . . . . . . . Neutrik PowerCon socket (accepts NAC3FCA connector)DM
26 MAC Viper Wash Safety and Installation GuideOrdering informationMAC Viper Wash™ in cardboard packing case . . . . . . . . . . . . . . . . . . . .
www.martin.com • Olof Palmes Allé 18 • 8200 Aarhus N • DenmarkTel: +45 8740 0000 • Fax +45 8740 0010
6 MAC Viper Wash User GuideEffects in the MAC Viper Wash DXThe MAC Viper Wash DX is supplied with an IBD projection module installed that contains in
Effects in the MAC Viper Wash DX 7• Slot 5 - Magenta 522 SP - P/N 46404570• Slot 6 - Deep Blue SP (Congo) - P/N 46404550• Slot 7 - Red 310 SP - P/N 4
8 MAC Viper Wash User GuideControl panel operationsYou can configure individual fixture settings (such as the MAC Viper Wash’s DMX address), read out
Control panel operations 9To activate the display when the fixture is not connected to power, press the Escape button. The display extinguishes after
Kommentare zu diesen Handbüchern