CX-4 user manual AC power connection 9
To rewire the power supply
1 Disconnect the fixture from AC power. Remove the top cover bolts with a 4
mm Allen wrench and lift off the cover.
2 On the transformer, which is located behind the color wheel, move the brown
and white wires to the transformer taps shown below for your mains voltage.
Do not move the blue wire from terminal 9 or the black wire from terminal 15.
Mains voltage Setting Brown White Blue Black
95 - 109 V 100 V 12 10
915
110 - 130 V 120 V 12 9
200 - 219 V 210 V 15 10
219 - 239 V 230 V 15 9
240 - 260 V 250 V 16 9
Table 2: Transformer settings
1 1 12 13 1 1 19
23456781
orange
orange
blue
white
black
brown
210 V
1 1 12 13 1 1 19
23456781
orange
orange
blue
white
black
brown
230 V
1 1 12 13 1 1 19
23456781
orange
orange
blue
white
black
brown
250 V
1 1 12 13 1 1 19
23456781
orange
orange
blue
white
black
brown
100 V
1 1 12 13 1 1 19
23456781
orange
orange
blue
white
black
brown
120 V
Kommentare zu diesen Handbüchern